Armored Removable AC Metal Enclosed Switchgear Power Distribution

WENZHOU QIUPU ELECTRIC POWER CO., LTD.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment

Armored Removable AC Metal Enclosed Switchgear Power Distribution

Brand Name : Qiupu

Model Number : KYN61

Certification : GB17467

Place of Origin : Zhejiang, China

MOQ : Negotiable

Price : Negotiable

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 5000

Delivery Time : 7 days

Product Name : High voltage AC metal enclosed switchgear

Rated voltage : 40.5kv

Protection degree : IP3X

Rated frequency : 50hz

Rated current : 1250,1600,2000,2500A

Contact Now

KYN61-40.5 High voltage AC metal enclosed switchgear customized by professional switchgear manufacturer

Product description

KYN61-40.5 armored removable AC metal-enclosed switchgear (hereinafter referred to as switchgear) three-phase AC 50Hz, rated voltage 40.5kV indoor complete power distribution device. As power plants, substations, and industrial and mining enterprises to receive and distribute electric energy, it can control, protect and monitor circuits, and can also be used in places with frequent operations.
This switchgear complies with GB3906-2006 "3~35kV AC Metal-enclosed Switchgear", GB/T11022-1999 "High Voltage Switchgear and Control Equipment Standard Common Technical Requirements" and DL/T 404-2007 "3.6kV~40.5kV AC Metal-enclosed switchgear and control equipment" and other standards.

Model and its meaning

Armored Removable AC Metal Enclosed Switchgear Power Distribution

①Metal armored switchgear

②Removable

③Indoor

④Design serial number

⑤Rated voltage (kV)

⑥Type of circuit breaker: Z-vacuum; SF6-sulfur hexafluoride

⑦Rated current

⑧Rated short-circuit breaking current (kA)

Scope of application

•Ambient temperature: upper limit +40°C, and the average value measured within 24h does not exceed 35°C, lower limit -10°C; •Altitude: altitude does not exceed 1000m;
•Relative humidity: the daily average value does not exceed 95%, and the monthly average value does not exceed 90%;
•Earthquake intensity: no more than 8 degrees;
• Water vapor pressure: the daily average value does not exceed 2.2kPa, and the monthly average value does not exceed 1.8kPa;
Surrounding environment: a place where there is no fire, explosion hazard, serious pollution, chemical corrosion and severe vibration.

Technical Parameters

Name Unit parameter
Rated voltage kV 40.5
Rated current A 1250 1600 2000
Rated frequency Hz 50
Rated short-time withstand current kA 20 25 31.5
Rated peak withstand current kA 50 63 80
Rated power frequency withstand voltage kV 95/lmin
Rated lightning impulse withstand voltage kV 185
Rated short-circuit duration s 4
Protection level IP3X

Installation dimension drawing

Armored Removable AC Metal Enclosed Switchgear Power Distribution

A. Busbar room
B. Handcart room
C. Cable room
D. Relay instrument room
1. Lifting ring
2. Main bus
3. Cover ring for small busbar compartment
4. Instrument room door
5. Branch bus
6. Bus bushing
7. Hornworm head box
8. Analog bus coil
9. Nameplate
10. Lighting
11. Handcart room door
12. Current transformer
13, hairpin chain
14. Insulator
15. Zinc oxide arrester
16. Insulating partition
17. Grounding switch
18. Valve assembly
19. Vacuum circuit breaker handcart
20. Small busbar terminal room

Need to know when ordering

Users need to provide the following information if ordering
• The main circuit plan number, purpose, single-line system diagram, arrangement diagram and power distribution room layout diagram, etc.;
• Auxiliary circuit wiring schematic diagram and terminal arrangement diagram;
• The model, specification and quantity of electrical components in the switchgear;
• Requirements for control, measurement and protection functions of switchgear, as well as requirements for other locking and automatic devices;
• If a bus bridge connection is required between switchgears or incoming cabinets, the rated current carrying capacity of the bus bridge, the span of the bus bridge, the height from the ground and other specific requirements data should be provided; • When accessories and spare parts are needed, the types and quantities should be provided;
• The switchgear is used in special environmental conditions and should be specified when ordering.


Product Tags:

AC Metal Enclosed Switchgear

      

Removable Metal Enclosed Switchgear

      

Armored Metal Enclosed Switchgear

      
Wholesale Armored Removable AC Metal Enclosed Switchgear Power Distribution from china suppliers

Armored Removable AC Metal Enclosed Switchgear Power Distribution Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: WENZHOU QIUPU ELECTRIC POWER CO., LTD.
*Subject:
*Message:
Characters Remaining: (0/3000)